Intelligent quantitative control instrument
Description
overview
Intelligent flow quantitative control instrument (hereinafter referred to as the controller) main features:
Suitable for all kinds of liquid media flow display, integration, quantitative control functions;
Input a variety of flow sensor signals (such as vortex street, turbine, electromagnetic, roots, elliptical gear, double rotor, orifice plate, V-cone, A Niuba, mass flow meter);
Flow input channel: can receive frequency signals and a variety of analog current signals;
Temperature input channel: can receive a variety of analog current signals;
Can provide transmitter +24V DC, +12V DC power supply, with short circuit protection function, simplify the system, save investment;
Fault tolerance function: When the temperature/density compensation measurement signal is abnormal, the corresponding manual setting value is used for compensation calculation;
Flow retransmit function, output flow current signal, update cycle 1 second, to meet the needs of automatic control;
Instrument clock and timing automatic meter reading function, printing function, to provide convenience for measurement management;
Rich self-test and self-diagnosis functions make the meter easier to use and maintain;
Three-level password setting can prevent unauthorized personnel from changing the set data;
The instrument is not equipped with any adjustable devices such as potentiometer, coding switch, so as to improve the seismic resistance, stability and reliability of the instrument;
Communication function: It can communicate with the host computer through various communication methods to form an energy metering network system:
RS-485;
RS-232;
The main technical indicators of the instrument
Input signal
Modular fitting:
Thermocouple: Standard thermocouple -- K, E, B, J, N, T, S;
Electrical resistance: standard thermal resistance -- Pt100;
Current: 0 ~ 10mA, 4 ~ 20mA -- input impedance ≤250Ω;
Pulse impulse:
Wave shape: rectangle, sine wave and triangle wave;
Amplitude: greater than 4V;
Frequency: 0 ~ 10KHz (or according to user requirements).
Output signal
Analog output:
DC 0 ~ 10mA (load resistance ≤750Ω);
DC 4 ~ 20mA (load resistance ≤500Ω);
Switching output
Relay output -- back error, AC220V/3A; DC24V/6A (resistive load).
Communication output
Interface mode -- standard serial communication interface: RS-232C, RS-485;
Baud rate - 600, 1200, 2400, 480, 9600Kbps, instrument internal Settings.
Feed output
DC24V, load ≤100mA;
DC12V: Load ≤200mA
specificity
Measurement accuracy: ±0.2%FS±1 word or ±0.5%FS±1 word
Frequency conversion accuracy: ±1 pulse (LMS) is generally better than 0.2%
Measuring range: -999999 ~ 999999 words (instantaneous value, compensation value);
0 ~ 99999999.9999 words (cumulative value)
Resolution: ±1 word
Display mode
· 128×64 dot matrix LCD graphic display with large backlit screen;
· Historical cumulative flow, instantaneous flow, medium temperature, medium density, flow (differential pressure current, frequency) value, clock, alarm status;
·0 ~ 999999 Instantaneous flow rate
·0 ~ 99999999.9999 Cumulative value
·-9999 ~ 9999 temperature compensation
·-99999 ~ 999999 Flow (differential pressure, frequency) value
Message