DisclaimerSiteMapChineseEnglish

Liquid level gauge

  • 1.jpg

Antiseptic type magnetic flap level gauge

Anticorrosive type liquid level meter is characterized by the liquid medium and the indicator is co
Description

Anticorrosive type liquid level meter is characterized by the liquid medium and the indicator is completely isolated, so in any case is very safe, reliable, durable, and various types of liquid level meter with level alarm, control switch, can realize the level or boundary offside alarm, control or interlock, with static pressure type liquid level transmitter or spring resistance type liquid level transmitter, The liquid level and boundary signal can be converted into 2-wire 4-20mADC standard signal to realize remote indication, detection, recording and control. It is suitable for measuring liquid level in corrosive medium and high working temperature. It has reliable structure and long service life. It is the choice of hydrofluoric acid and other strong corrosive medium liquid level measurement. Customized for customers, the temperature and pressure requirements are not high can use the company's PP material level meter.


Stainless steel lining PTFE anti-corrosion magnetic level meter using stainless steel body lining polypropylene (PP) and PTFE process, has high structural strength and corrosion resistance, can be applied to acid liquid, alkaline liquid and organic solvents such as hydrochloric acid. However, it is not suitable for the measurement of concentrated nitric acid, chlorinated solvent, aromatic agent, aliphatic liquid and other medium. Side mounted lining anti-corrosion magnetic flap level meter with stainless steel main lining polytetrafluoroethylene (PTFE) and stainless steel lined polypropylene (PP) two, suitable for the measurement of corrosive media.


Side mounted lined magnetic flap liquid level meter (PTFE) is suitable for corrosive media and high working temperature and liquid level measurement, using stainless steel lined PTFE stretching flanging new process, reliable structure, long service life. It is the choice of hydrofluoric acid and other strong corrosive medium liquid level measurement.

Side mounted magnetic flap liquid level meter (PP) is suitable for the measurement of hydrochloric acid, dilute sulfuric acid and other inorganic corrosive liquid, due to the use of imported high strength can be close to metal, especially the thermal insulation of PPR, the product is suitable for outdoor water tank liquid level measurement, in winter internal will not freeze, but not as good as PTFE type temperature and pressure resistance, This product is more cost-effective when the temperature and pressure are low. Users can use the remote transmission transmitter according to the engineering needs, can realize the local digital display, and output 4~20mA standard remote transmission electrical signal, to meet the needs of recording instruments, or industrial process control. It can also be used with magnetic control switch or proximity switch to monitor and alarm liquid level or to control liquid inlet and outlet equipment.


Anti-corrosion type magnetic flip plate liquid level meter features:


1, float as the measuring element, magnetic steel drive flip column display, no energy.


2, equipped with upper and lower limit switch output, can realize remote alarm, limit control.


3, the distribution transmitter can realize the liquid level remote indication, detection and control.


Installation and maintenance of anti-corrosion magnetic flap level gauge


1. The liquid level gauge shall be installed vertically to ensure that the float assembly can move freely up and down in the main pipe.


2. No magnetometer is allowed around the main body of the level meter, otherwise it will directly affect the correct operation of the level meter.


3. After the liquid level meter is installed, it is necessary to correct the tilting column with magnetic steel so that the following zero is displayed in red and the above zero is displayed in white.


4. When the liquid level gauge is put into operation, the valve of the lower primer pipe should be opened first to let the liquid medium enter the main pipe smoothly, so as to avoid the rapid rise of the liquid medium with the floating ball component, which causes the turning column failure and disorderly turning. If this phenomenon occurs after the liquid level is stable, magnetic steel can be re-corrected.


Basic technical parameters


1, measuring range: 300 ~ 4000㎜ (more than 5000mm can be specially customized)


2, display accuracy: ±10mm;


3, working pressure: PP: normal pressure


4, medium temperature: PP: -20 ~ 70℃;


5, medium density: ≥0.5g/cm3;


6, medium viscosity: ≤0.4Pa·S;


7, process connection: DN2025/50/80/150 PN1.0 (implementation standard HG20592~20635-97), if you need other standards can be manufactured according to customer requirements.


8, liquid material: /PP and so on


9, float material: 316L, PVC/UPVC/CPVC/PP, PTFE, titanium, etc.


Message
Return To The Top