DisclaimerSiteMapChineseEnglish

Liquid level gauge

  • 1.jpg

Side mounted magnetic flap level gauge

I. Product Overview Overview of the product UHZ series side mounted magnetic flap liquid level gau
Description

I. Product Overview Overview of the product


UHZ series side mounted magnetic flap liquid level gauge products can achieve high sealing, leakage prevention and safe and reliable measurement of liquid level under high temperature, high pressure, high viscosity, strong corrosion conditions, the whole process of measurement without blind area, eye-catching display, intuitive reading


Technical parameters:

1. Installation mode: side loading type and top loading type

2, measurement media: such as water, oil, other chemical solvents and liquid raw materials

3, material requirements: such as 304 stainless steel, 316L stainless steel, stainless steel lined with tetrafluor. PP, PVC (if the user is not clear, after providing relevant parameters, our technical staff can help select)

4, measuring the temperature of the medium: the different temperature determines the different choice of float and display panel material type. When the temperature is too low in winter, it is necessary to install potential heat or steam jacket for insulation. The medium temperature can be measured by the liquid level meter -20℃~500℃.

5, working pressure: the size of the pressure determines the thickness of the leading pipe and welding and other processing technology is different. The liquid level meter can measure the medium z.u high pressure up to 10MPa.

6. Connection mode: Top mounted magnetic flap level gauge series products generally use the connection flange of DN80 or DN100. There are three connection modes for side mounted magnetic flap level gauge: flange connection (such as DN25), clamp connection and thread connection.

7. Measuring range:


1. Side mounted because it is connected with the vessel to be measured through the upper and lower two catheters, the measuring range is the distance between the center of the two catheters, referred to as the center distance. 2. The top-mounted type is inserted into the container from the top, so its measuring range is the distance to be measured between the top and the bottom of the container.




8, far transmission and alarm signal: magnetic flap liquid level meter can achieve far transmission 4-20mA, 485 communication, Modbus protocol and switching signal, alarm function.


Two, the side mounted magnetic flip plate liquid level gauge working principle


A new type of instrument in which the magnetic steel in the float drives a two-color sheet to turn over to indicate the liquid level. The maglev inside the main body of the liquid level gauge moves up and down with the rise and fall of the liquid level, and drives the two-color sheet inside the indicator outside the main body to turn over. When there is a liquid level, it shows red, and when there is no liquid level, it shows white. The boundary between the red and white bands represents the liquid level. There is a striking scale on the left side of the indicator.


Classification and application of magnetic flap liquid level gauge


Three, side mounted magnetic flip plate liquid level gauge main technical indicators:


1, measuring range (mm) : measuring range: 300~18000mm


2, medium density (g/cm3) : 0.5 ~ 2


3, medium viscosity: ≤0.02Pa.S


4, working temperature: -40 ~ 350


5, working pressure: ≤2.5MPa (ordinary type)


≤10.0MPa (high pressure type)


≤32.0MPa (ultra-high pressure type)


≤2.5MPa (anticorrosive type)


6, measurement accuracy (mm) : ≤±10


7. Installation mode: side mounted magnetic flip plate liquid level gauge, top mounted, bottom mounted


8. Protection level: IP65


9, explosion-proof grade: ibⅡCT4 (intrinsic safety type), dⅡBT4 (flameproof type)

10, transmission mode: 4 ~ 20mA or switch quantity


11, interface flange: according to the national Ministry of Chemical Industry, Ministry of machinery and American standards, can be customized according to the needs of users.


Note: When the installation of side mounted magnetic flap level gauge is affected by the environment, the spatial position L1<300 should be clearly put forward when ordering.


Message