DisclaimerSiteMapChineseEnglish

Bimetal thermometer

  • 1.jpg

Hot jacket bimetallic thermometer

I. Overview of instrument: Hot jacket bimetal thermometer is a kind of field detection instrumen
Description

I. Overview of instrument:

Hot jacket bimetal thermometer is a kind of field detection instrument suitable for measuring medium and low temperature, which can be used to directly measure the temperature of gas, liquid and steam. From the design principle and structure, the thermometer has the characteristics of waterproof, anti-corrosion, flame-proof, shock resistance, intuitive, easy reading, no mercury damage, strong and durable. A measuring instrument that can replace other forms.

Two, measurement principle:

It works on the principle that two different metals expand differently when temperature changes. The main element of a bimetallic thermometer for industrial use is a multilayer metal sheet made up of two or more metal sheets pressed together. In order to improve the sensitivity of bimetallic thermometers, metal sheets are usually made into spiral coils. When the temperature of the multilayer metal sheet changes, the expansion or contraction of each layer of metal varies, making the spiral coil rolled up or loosened. Since one end of the coil is fixed and the other end is connected to a freely rotating pointer, when the bimetal feels the temperature change, the pointer can indicate the temperature on a circular indexing scale.

Three, application:

Suitable for various installation sleeves, to meet the requirements of different pressure levels. It can directly measure the temperature of liquid, steam and gas medium and solid surface in the range of -80-+500℃ in various production processes.

Four, performance characteristics:

1, the field display temperature, intuitive and convenient, safe and reliable, long service life and so on.

2, no mercury damage, easy reading, strong and shock-resistant.

3. The protective pipe is 1Gr18Ni9Ti stainless steel and molybdenum dititanium, with strong pressure and anti-corrosion ability.

4, the core type thermometer can not stop for a short time to maintain or replace the movement.

V. Technical Indicators:

Implementation standard

JB/T8803-1998 GB3836-83.

Other parameters

Nominal diameter of dial: 60,100,150;

Accuracy level: (1.0), 1.5;

Thermal response time: ≤40S;

Protection level: IP55;

Angle adjustment error: Angle adjustment error shall not exceed 1.0% of its range;

Return error: bimetal thermometer return error should not be greater than the basic error limit;

Repeatability: The repeatability limit of bimetallic thermometers should not be greater than 1/2 of the basic error limit.

Six, precautions

1, can not directly twist the watch head;

2, length selection to choose close to the standard size (50mm integer multiple);

3. The length of the protective tube immersed in the measured medium must be greater than the length of the temperature sensing element. Generally, the immersion length is recommended to be greater than 100mm, and the immersion length of 0-50℃ range is recommended to be greater than 150mm, so as to ensure the accuracy of measurement.

4, bimetal thermometer should not be used to measure the temperature of the medium in the open container.

5, in the custody, use of installation and transportation, should avoid collision protection tube, do not make the protection tube bending deformation, more can not be used as a wrench table.

6, in the case of normal use should be regularly inspected. Generally every six months is appropriate.

7, do not allow to work in the strong vibration environment, so as not to shadow the bimetal life, electric contact bimetal thermometer is not allowed to be used in the vibration of the larger occasions of the control loop, so as not to affect the reliability.

Seven, temperature range:

Measuring range ℃

Scope of application

Industry and commerce

Laboratory, small

-80 to +40

Square root

Square root

-40 to +80

Square root

Square root

0 ~ 50

Square root

Square root

0 to 100

Square root

Square root

0 ~ 150

Square root

Square root

0 ~ 200

Square root

Square root

0 ~ 300

Square root

Square root

0 ~ 400

Square root

Square root

0 ~ 500

Square root

Square root

Viii. Overall Size:

form

D

A

B

E

d

Radial type

105

23

73


Ф 8

Ф 10

155

23

73


Axial type

65

50

110

34

105

50

110

34

Universal type

105

23

178

120

155

23

178

120

Electric contact

Axial type

128

40

135


Electric contact

Radial type

128

72

150

42

Electric contact

Universal type

128

40

175

98

Ix. Models and Specifications:

Type number

Temperature range

Precision class

Protective tube material

Gauge lattice

Nominal pressure

Casing form

WSS-403S

- 80-40 +

- 40 - + 80

0 to 50

0-100.

0-150.

0-200.

0-300.

0-400.

0-500.

1. 5

1Cr18Ni9Ti

 

304

316

316L

Hastelloy C-276

75

100

150

200

300

30 mpa or less

Threaded connection

WSS-503S

WSS-413S

WSS-513S

WSS-483S

WSSX-413S

WSSX-483S

WSS-403L

150-40MPa

Flanged joint

WSS-503L

WSS-413L

WSSX-503L

WSS-483L

WSS-583L

WSSX-403L

WSSX-483L

Note: Bimetal thermometers can be equipped with various mounting sleeves. See the hot mounting sleeves for details. The rest of the material of the protection tube is ordered according to the agreement: hit * indicates nominal pressure according to the flange pressure grade.


Message