DisclaimerSiteMapChineseEnglish

Bimetal thermometer

  • 1.jpg

Stainless steel bimetal thermometer

Working principle of stainless steel bimetal thermometer Bimetallic thermometer is a single need
Description

Working principle of stainless steel bimetal thermometer

Bimetallic thermometer is a single needle indicating thermometer that uses a bimetallic sheet wound into a spiral tube, one end is fixed, the other free end is connected with the needle, and rotates with the change of temperature, and drives the needle to rotate to indicate the temperature.

Main technical characteristics of stainless steel bimetal thermometer

Temperature measurement range: -80-600℃

Accuracy level: 1.0/1.5,

The indicating part of the thermometer: (according to the outer diameter of the thermometer dial) divided into φ60, φ100, φ150mm.

Liner length: 100-2000mm.

Liner diameter: φ6, φ10, (liner length 100-1250mm) φ12 (liner length 1250-2000mm)

Mounting part thread :M16X1.5; M27X2; G1/2; G3/4. Liner tube and fixing bolt joint are made of 1Cr18Ni9Ti stainless steel, withstand pressure 6.4MPa.

 

Temperature range

Measuring range ℃Scope of application
Industry and commerceLaboratory, small
-80 to +40Square rootSquare root
-40 to +80Square rootSquare root
0 ~ 50Square rootSquare root
0 to 100Square rootSquare root
0 ~ 200Square rootSquare root
0 ~ 300Square rootSquare root
0 ~ 400Square rootSquare root
0 ~ 500Square rootSquare root
0 ~ 600Square rootSquare root

Overall dimension

formABCELd
Axial type652373-75
100
150
200
300
400
500
750
1000
Φ 6
Φ 8
Φ 10
1052373-
1552373-
Radial type655011034
1055011034
1055011034
135° orientation1052385-
1552385-
Universal type10523178120
15523178120

Selection coding

Series number WSS
Bimetal thermometer
Nominal diameter of dial- 3
Φ 60
4 -
Φ 100
- 5
Φ 150
Dial form 0
Axial (straight type)
 1
Radial (angular)
 2
135° direction (obtuse Angle)
 8
Universal (adjustable Angle type)
Mounting and fixing form 0
Unfixed device
 1
Movable external thread
 2
Internal thread can be moved
 3
Fixed thread
 4
Fixed flange
 5
Jacketed thread
 6
Sleeve flange
Form of protection-
Ordinary type
 W
Protective type
 F
Antiseptic type

Model and specification Axial bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-300
-40 to +80
-80 to +40
0 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 6075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-400Φ 100
WSS-500Φ 150
WSS-301Φ 60Movable external thread
WSS-401Φ 100
WSS-501Φ 150
WSS-302Φ 60Internal thread can be moved
WSS-402Φ 100
WSS-502Φ 150
WSS-303Φ 60Fixed thread
WSS-403Φ 100
WSS-503Φ 150
WSS-304Φ 60Fixed flange
WSS-404Φ 100
WSS-504Φ 150
WSS-305Φ 60Jacketed thread
WSS-405Φ 100
WSS-505Φ 150
WSS-306Φ 60
WSS-406Φ 100Sleeve flange
WSS-506Φ 150

Radial bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-310
-40 to +80
0 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 6075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-410Φ 100
WSS-510Φ 150
WSS-311Φ 60Movable external thread
WSS-411Φ 100
WSS-511Φ 150
WSS-312Φ 60Internal thread can be moved
WSS-412Φ 100
WSS-512Φ 150
WSS-313Φ 60Fixed thread
WSS-413Φ 100
WSS-513Φ 150
WSS-314Φ 60Fixed flange
WSS-414Φ 100
WSS-514Φ 150
WSS-315Φ 60Jacketed thread
WSS-415Φ 100
WSS-515Φ 150
WSS-316Φ 60
WSS-416Φ 100Sleeve flange
WSS-516Φ 150

Universal type bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-480
-40 to +80
-80 to +40
0 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 10075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-580Φ 150
WSS-481Φ 100Movable external thread
WSS-581Φ 150
WSS-482Φ 100Internal thread can be moved
WSS-582Φ 150
WSS-483Φ 100Fixed thread
WSS-583Φ 150
WSS-484Φ 100Fixed flange
WSS-584Φ 150
WSS-485Φ 100Jacketed thread
WSS-585Φ 150
WSS-486Φ 100Sleeve flange
WSS-586Φ 150

135° directional bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-4200 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 10075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-520Φ 150
WSS-421Φ 100Movable external thread
WSS-521Φ 150
WSS-422Φ 100Internal thread can be moved
WSS-522Φ 150
WSS-423Φ 100Fixed thread
WSS-523Φ 150
WSS-424Φ 100Fixed flange
WSS-524Φ 150
WSS-425Φ 100Jacketed thread
WSS-525Φ 150
WSS-426Φ 100Sleeve flange
WSS-526Φ 150
 

 

Installation requirements

On the installation of bimetal thermometer, attention should be paid to the accuracy of temperature measurement, safety can be checked and convenient maintenance, and does not affect the operation and production of equipment, to meet the above requirements, in the selection of thermal resistance installation site and insertion depth should pay attention to the following points:

(1) In order to ensure sufficient heat exchange between the measuring end of the thermal resistance and the measured medium, the position of the measuring point should be selected reasonably, and the thermal resistance should be installed near the dead Angle of the valve, elbow and pipe and equipment as far as possible.

(2) Thermal resistance with protective sleeve has heat transfer and heat dissipation loss. In order to reduce measurement errors, the thermocouple and thermal resistance should have sufficient insertion depth:

a. For the thermal resistance measuring the fluid temperature in the center of the pipe, the measuring end should generally be inserted into the center of the pipe (vertical installation or inclined installation). If the pipe diameter of the measured body is 200 mm, the insertion depth of the thermal resistance should be selected to be 100 mm;

b. For the temperature measurement of high temperature, high pressure and high speed fluids (such as the temperature of the main steam), in order to reduce the resistance of the protective sleeve to the fluid and prevent the fracture of the protective sleeve under the action of the fluid, the shallow insertion of the protective tube or the hot sleeve type thermal resistance can be adopted. The depth of the shallow plug type thermal resistance protection sleeve inserted into the main steam pipe shall not be less than 75mm; The standard insertion depth of hot-sleeve resistance is 100mm;

c. If the temperature of the flue gas in the flue is to be measured, the insertion depth of the thermal resistance can be 1 m, although the diameter of the flue is 4m;

d. When the insertion depth of the measured element exceeds 1m, it shall be installed vertically as far as possible, or support frame and protective sleeve shall be installed.


Message