Bimetal thermometer

  • 1.jpg

Bimetal thermometer

I. Product overview WSS series bimetal thermometer is a field instrument for measuring low and m
Description

I. Product overview

WSS series bimetal thermometer is a field instrument for measuring low and medium temperature. Bimetallic thermometers can directly measure the temperature of liquid, steam and gas medium in the range of -80℃ ~ +600℃ in various production processes. The structure of bimetallic thermometers can be divided into radial, axial and universal forms, as shown in Figure 1. Different installation structures are different.


Two, the main characteristics

On-site temperature display, intuitive and convenient; Safe and reliable, long service life; A variety of structural forms, can meet different requirements.

 

Three, the working principle

Bimetallic thermometers are based on a bimetallic sheet wound into a circular bend. When one end is heated and expanded, it drives the pointer to rotate, and the working instrument displays the temperature value.

 

Iv. Technical parameters

1, the nominal diameter of the scale plate: 60mm, 100mm, 150mm

2, accuracy level: 1.0, 1.5

3. Thermal response time: ≤40S

4. Protection level: IP55

5, Angle adjustment error: Angle adjustment error should not exceed 1.0% of its range

6, back error: bimetal thermometer back error should not be greater than the basic error limit J.D value

7, repeatability: bimetallic thermometer repeatability limit range should not be greater than the basic error limit J.D value 1/2

 

Five, temperature range

Measuring range ℃Scope of application
Industry and commerceLaboratory, small
-80 to +40Square rootSquare root
-40 to +80Square rootSquare root
0 ~ 50Square rootSquare root
0 to 100Square rootSquare root
0 ~ 200Square rootSquare root
0 ~ 300Square rootSquare root
0 ~ 400Square rootSquare root
0 ~ 500Square rootSquare root
0 ~ 600Square rootSquare root

Vi. Overall dimensions

formABCELd
Axial type652373-75
100
150
200
300
400
500
750
1000
Φ 6
Φ 8
Φ 10
1052373-
1552373-
Radial type655011034
1055011034
1055011034
135° orientation1052385-
1552385-
Universal type10523178120
15523178120

Seven, selection and coding

Series number WSS
Bimetal thermometer
Nominal diameter of dial- 3
Φ 60
4 -
Φ 100
- 5
Φ 150
Dial form 0
Axial (straight type)
 1
Radial (angular)
 2
135° direction (obtuse Angle)
 8
Universal (adjustable Angle type)
Mounting and fixing form 0
Unfixed device
 1
Movable external thread
 2
Internal thread can be moved
 3
Fixed thread
 4
Fixed flange
 5
Jacketed thread
 6
Sleeve flange
Form of protection-
Ordinary type
 W
Protective type
 F
Antiseptic type

8. Models and Specifications Axial bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-300
-40 to +80
-80 to +40
0 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 6075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-400Φ 100
WSS-500Φ 150
WSS-301Φ 60Movable external thread
WSS-401Φ 100
WSS-501Φ 150
WSS-302Φ 60Internal thread can be moved
WSS-402Φ 100
WSS-502Φ 150
WSS-303Φ 60Fixed thread
WSS-403Φ 100
WSS-503Φ 150
WSS-304Φ 60Fixed flange
WSS-404Φ 100
WSS-504Φ 150
WSS-305Φ 60Jacketed thread
WSS-405Φ 100
WSS-505Φ 150
WSS-306Φ 60
WSS-406Φ 100Sleeve flange
WSS-506Φ 150

Radial bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-310
-40 to +80
0 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 6075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-410Φ 100
WSS-510Φ 150
WSS-311Φ 60Movable external thread
WSS-411Φ 100
WSS-511Φ 150
WSS-312Φ 60Internal thread can be moved
WSS-412Φ 100
WSS-512Φ 150
WSS-313Φ 60Fixed thread
WSS-413Φ 100
WSS-513Φ 150
WSS-314Φ 60Fixed flange
WSS-414Φ 100
WSS-514Φ 150
WSS-315Φ 60Jacketed thread
WSS-415Φ 100
WSS-515Φ 150
WSS-316Φ 60
WSS-416Φ 100Sleeve flange
WSS-516Φ 150

Universal type bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-480
-40 to +80
-80 to +40
0 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 10075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-580Φ 150
WSS-481Φ 100Movable external thread
WSS-581Φ 150
WSS-482Φ 100Internal thread can be moved
WSS-582Φ 150
WSS-483Φ 100Fixed thread
WSS-583Φ 150
WSS-484Φ 100Fixed flange
WSS-584Φ 150
WSS-485Φ 100Jacketed thread
WSS-585Φ 150
WSS-486Φ 100Sleeve flange
WSS-586Φ 150

135° directional bimetallic thermometer

Model numberTemperature rangePrecision classProtective tube materialspecificationMounting and fixing form
DL
WSS-4200 ~ 50
0 to 100
0 ~ 150
0 ~ 200
0 ~ 300
0 ~ 400
0 ~ 500
0 ~ 600
1.51Cr18Ni9Ti
304
316
316L
Hastelloy C-276
Φ 10075
100
150
200
300
400
500
750
1000
Unfixed device
WSS-520Φ 150
WSS-421Φ 100Movable external thread
WSS-521Φ 150
WSS-422Φ 100Internal thread can be moved
WSS-522Φ 150
WSS-423Φ 100Fixed thread
WSS-523Φ 150
WSS-424Φ 100Fixed flange
WSS-524Φ 150
WSS-425Φ 100Jacketed thread
WSS-525Φ 150
WSS-426Φ 100Sleeve flange
WSS-526Φ 150


Remarks:

Instructions for selection: Please provide the model, dial diameter, precision grade, installation and fixed form, temperature range, protective tube material, length or insertion depth. Selection example: universal bimetallic thermometer, dial diameter Φ100, temperature range 0 ~ 400℃, 1.5 class, movable external thread M27×2, length 450mm WSS-481, 0 ~ 400℃, L=450, M27×2, 1.5 class


Message