Thermal resistance

  • 1.jpg

Flameproof platinum resistance

Industrial flameproof platinum resistor is a temperature sensor. Widely used in the industrial auto
Description

Industrial flameproof platinum resistor is a temperature sensor. Widely used in the industrial automatic control system, through the temperature sensor, the temperature parameters of the control object into electrical signals, transferred to the display, record and adjust the instrument, the system to detect, adjust and control. In chemical plants, production sites are often accompanied by a variety of flammable, explosive and other chemical gases, vapors, if the use of ordinary platinum resistance is very unsafe, easy to cause environmental gas explosion. Therefore, in these occasions must use flameproof thermocouple as a temperature sensor, the factory production of flameproof platinum resistance products are suitable for d II BT4~d II CT6 temperature group within the site with explosive gas danger, the factory production of flameproof thermocouple with the introduction of components as temperature sensing components, Its technical performance conforms to ZBY301-85 industrial platinum electrical technical conditions and index table. At the same time, the products meet the general requirements of explosion-proof electrical equipment for explosive environment GB3836.1-83, GB3836.2-83 standards.

Main technical index

Range specification

Model number

Dividing sign

Temperature range: ° C

Precision class

Allowable deviation △ t ℃

WZP 
WZP 2 
WZPK 
WZPK 2 
PT100- 200 ~ 500Class APlus or minus (0.15 + 0.002 | t |)
Class BPlus or minus (0.30 + 0.005 | t |)

Note: "t" is the measured temperature value of the temperature sensing element, and the double platinum resistor is only available at grade B

The thermal resistance allows the measurement of current through the platinum resistance to a maximum of 5mA. Explosion-proof class: d II BT4 or d II CT4; d II BT6 or d II CT6 case protection class: IP54

The structure and principle of flameproof thermal resistance and assembled thermal resistance are basically the same. The difference is that the junction box (shell) of flameproof products adopts explosion-proof special structure in the design. The junction box is made of high strength aluminum alloy die-cast, and has enough internal space, wall thickness and mechanical strength. Therefore, when the explosive mixture inside the junction box explodes, its internal pressure will not damage the junction box, and the resulting heat energy cannot be diffused outwards -- detonation. As the product adopts the above explosion-proof special structure, the product is fully in line with the use of d II BT4 to d II CT6 explosion-proof temperature group range, as long as the user strictly abide by the product rules, the product can achieve reliable explosion-proof effect. Electrical equipment category, grade and temperature group description: electrical equipment is divided into two categories: I - coal mine underground electrical equipment; Class II - factory electrical equipment explosion-proof grade flameproof thermal resistance of the explosion-proof grade mechanical It is suitable for explosive gas mixture the maximum safety gap is divided into A, B, C three. Temperature group flameproof tropical internal resistance of the temperature group according to its exposed part of the highest surface temperature is divided into T1~T6 six groups. Types and specifications of flameproof thermal resistors

categoryModel numberDividing signTemperature range: ° CProtective tube
material
Thermal response time t0.5sNominal pressure MpaStructural featurespecificationExplosion-proof rating
Total length L (mm)Insertion depth l (mm)
Platinum thermal resistanceWZP-24SAPT100- 200 ~ 5001Cr18Ni9Ti stainless steel
Or 0Cr18Ni
12M02Ti
≤ 9010M27*2 flameproof junction box fixed flange installation250 350 400 450 550 650 900 1150100 200 250 300 400 500 750 1000d IIBT4 
d II BT6 or
d II CT4
d II CT6

WZP2-24SA

WZP-44SA

6.4

WZP2-44SA

WZP
    -64S 
WZP2 

1Cr18Ni9Ti30Conical protection tube M33*2250 350 450100 200 300

Types and specifications of flame-proof armored thermal resistors

categoryModel numberpoints
The degree of
No.
temperature
Range ℃
Protective tube
Diameter D
(mm)
Thermal response time t0.5sNominal pressure Mpastructure
characteristic
specificationexplosion-proof
grade
Total length L
(mm)
Insertion depth l
(mm)
Platinum thermal resistanceWZPK-24 
WZPK2-24 
PT100- 200 -
500
φ6
or
φ 5 
≤ 12 
≤ 8
10 Flameproof junction box fixed screw mounting M27*2300 
350 
450 
550 
650 
900 
1150 
150 
200 
300 
400 
500 
750 
1000 
d IIBT4 
d IIBT6 
or
d IICT4 
d IICT6 
WZPK-44
WZPK2-44

6.4

Flanging of flameproof junction box

 



Message