Thermocouple

  • 1.jpg

Furnace wall thermocouple

application Furnace wall thermocouple is the diameter of Φ4 or Φ5 armored thermocouple original
Description

application

Furnace wall thermocouple is the diameter of Φ4 or Φ5 armored thermocouple original as the temperature probe, measuring end with screws, hoop or welding (using the original thermal resistance should not be welded) and other ways to measure the temperature probe and the surface of the thermal conductive plate tightly together, the other side of the thermal conductive plate has the same curved surface as the measured surface, The temperature of the furnace wall or tube wall can be measured when the heat conduction plate is welded or the clamp is tightly attached to the furnace wall under test. Furnace wall thermocouple is suitable for measuring temperature of furnace wall, tube wall and other cylindrical surface of power plant boiler.

Main technical parameters

◆ Nominal pressure: normal pressure ◆ Bending radius: R≥5D

Models and specifications

Type number

Dividing sign

Temperature range: ° C

Measuring end type

Gauge lattice

L1

L

WRNT-11
WRNT2-11
WRNT-51
WRNT2-51

K

0 ~ 800

Insulated type

1000
2000
3000
4000
5000
6000
8000
10000
15000
20000
25000

1000
2000
3000
4000
5000
6000
8000
10000
15000
20000
25000

WRET-11
WRET2-11
WRET-51
WRET2-51

E

0 ~ 600

WRNT-12
WRNT2-12

K

0 ~ 800

Shell type

WRET-12
WRET2-12

E

0 ~ 600


Note: 1) Class Ⅰ thermocouple, class A thermal resistance order according to the agreement; 2) The material of the protective tube is 1Cr18Ni9Ti, and the rest materials shall be ordered according to the agreement.