KC compensating conductor
Description
Intrinsical safety explosion-proof temperature measuring system with compensation wire or cable using low capacitance, low inductance material structure, with explosion-proof safety performance, suitable for dangerous environment for explosion-proof thermocouple cold short and explosion-proof thermometer table connection, the formation of a thermocouple temperature measuring system.
Two: product implementation standards
GB/T4989-94(equivalent to IEC584-3 standard)
Three: Use features
1. Conductor maximum operating temperature: heat resistance grade: poly (perfluorinated ethylene propylene (F46)200℃
Soluble PTFE 260℃
Silicone rubber 180℃
Common grade: PVC 70℃ and 105℃, crosslinked polyethylene 90℃
Low smoke halogen-free flame retardant polyolefin 70℃, crosslinked type 90℃ and 125℃
2. Low ambient temperature: PVC sheath: -40℃ for fixed dressing, -15℃ for non-fixed dressing
Fluorine plastic insulation and sheathing: fixed laying -60℃, non-fixed laying -20℃
3. Allowable bending radius of cable: the minimum diameter of non-armored cable is 6 times
Copper tape shield or steel tape armor decorative cable is at least 12 times the cable diameter
Fluoroplastic insulation and sheathing should be at least 10 times the outer diameter of the cable
Four: Basic model and name KC KCP SC SCP EX EXP WC WCP KX KXP FF FFP........
1: Compensation wire for thermocouple
KX-GA-VV | Polyvinyl chloride insulated polyvinyl chloride sheathed thermocouple compensation conductor with J grade K grade |
KX-GA-VVR | Polyvinyl chloride insulated polyvinyl chloride sheathed thermocouple compensation flexible conductor |
KX-GA-VVP | PVC insulated PVC sheathed copper wire braided shielding J grade K grade thermocouple compensation conductor |
KX-GA-VVRP | PVC insulated PVC sheathed copper wire braided shielding J grade K grade thermocouple compensation flexible conductor |
KX-HA-FF | Fluoro-plastic insulated and sheathed thermocouple compensation conductor with J grade K grade |
KX-HA-FFR | Fluorinated plastic insulated and sheathed thermocouple compensation flexible conductor with J grade K grade |
KX-HA-FFP | Fluorine plastic insulation and sheathed copper wire braided shielding J grade K grade thermocouple compensation conductor |
KX-HA-FFRP | Fluorine plastic insulation and sheath copper wire braided shielding J grade K grade thermocouple compensation flexible conductor |
KX-HA-FG | Fluorine plastic insulated silicone rubber sheathed thermocouple compensation conductor with J grade K grade |
KX-HA-FGR | Fluorine plastic insulated silicone rubber sheathed J dense K grade thermocouple compensation flexible conductor |
KX-HA-FGP | Fluorine plastic insulation silicone rubber sheathed copper wire braided shield J grade K grade thermocouple compensation conductor |
KX-HA-FGRP | Fluorine plastic insulation silicone rubber sheathed copper wire braided shielding J grade K grade thermocouple compensation flexible conductor |
KX-HA-FV | Fluorine plastic insulated polyvinyl chloride sheathed thermocouple compensation conductor with J grade K grade |
KX-HA-FVR | Fluorinated plastic insulated polyvinyl chloride sheathed thermocouple compensation flexible conductor with J grade K grade |
KX-HA-FVP | Fluorine plastic insulated polyvinyl chloride sheathed copper wire braided shielding J grade K grade thermocouple compensation conductor |
KX-HA-FVRP | Fluorinated plastic insulated polyvinyl chloride sheathed copper wire braided shielding J grade K grade thermocouple compensation flexible conductor |
KX-GA-YJV | Crosslinked polyethylene insulated polyvinyl chloride sheathed thermocouple compensation conductor with J grade K grade |
KX-GA-YJVR | Crosslinked polyethylene insulated polyvinyl chloride sheathed thermocouple compensation flexible conductor |
KX-GA-YJVP | Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided shielding J grade K grade thermocouple compensation conductor |
KX-GA-YJVRP | Low smoke halogen-free insulation and sheathed copper wire braided shielding J grade K grade thermocouple compensation flexible conductor |
KX-GA-YDYD | Low smoke halogen-free insulated and sheathed J grade K grade thermocouple compensation conductor |
KX-GA- YDYD R | Low smoke halogen-free insulated and sheathed J grade K grade thermocouple compensation flexible conductor |
KX-GA- YDYD P | Low smoke halogen-free insulated and sheathed copper wire braided shielding J grade K grade thermocouple compensation conductor |
KX-GA- YDYD RP | Low smoke halogen-free insulation and sheathed copper wire braided shielding J grade K grade thermocouple compensation flexible conductor |
Note: Only KX is listed in the above models. For others such as SC, KC, EX, BC, TX and JX, you only need to change the model ******. Flame retardant compensation wire model before ZR, ZR192 is imported PFA material, Shielding can be tinned copper wire shielding. |
2: This type of thermocouple with compensation wire
IA-KX-GA-YVP | Polyethylene insulated polyvinyl chloride sheathed copper wire braided shield J grade K grade internal safety thermocouple compensation conductor |
IA-KX-GA-YVRP | Polyethylene insulated polyvinyl chloride sheathed copper wire braided shielding J grade K grade internal safety thermocouple compensation flexible conductor |
IA-KX-HA-FFP | Fluorine plastic insulation and sheathing copper wire braided shield J grade K grade internal safety thermocouple compensation conductor |
IA-KX-HA-FFRP | Fluorine plastic insulation and sheath copper wire braided shielding J grade K grade intrinsic safety thermocouple compensation flexible conductor |
IA-KX-HA-FGP | Fluorine plastic insulation silicone rubber sheathed copper wire braided shield J grade K grade internal safety thermocouple compensation conductor |
IA-KX-HA-FGRP | Fluorine plastic insulation silicone rubber sheathed copper wire braided shielding J grade K grade intrinsic safety thermocouple compensation flexible conductor |
Note: Only KX is listed in the above models. For others such as SC, KC, EX, NC, TX and JX, you only need to change the model ******. Flame retardant type in front of the model plus ZR, ZR192 for imported PFA material, Shielding can be tinned copper wire shielding. |
3: Compensation cable
KX-GA-VVP | PVC insulated and sheathed copper wire braided total shielding J grade K grade compensation cable for thermocouples |
KX-GA-VVRP | PVC insulated and sheathed copper wire braided total shielding J grade K grade compensated flexible cable for thermocouples |
KX-GA-VPVP | PVC insulated and sheathed copper wire braided split screen plus total shielding J grade K grade compensation cable for thermocouples |
KX-GA-VPVRP | Compensation flexible cable for PVC insulated and sheathed copper wire braided split screen plus total shielding J grade K grade thermocouple |
KX-GA-YJVP | Compensation cable for crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided total shielding J grade K grade thermocouple |
KX-GA-YJVRP | Compensation flexible cable for crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided total shielding J grade K grade thermocouple |
KX-GA-YJPVP | Compensation cable for crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen plus total shielding J grade K grade thermocouple |
KX-GAYJPVRP | Compensation flexible cable for cross-linked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen plus total shielding J grade K grade thermocouple |
KX-HA-FFP | Fluoroprene insulation and sheathed copper wire braided total shielding J grade K grade compensation cable for thermocouples |
KX-HA-FFRP | Fluoroprene insulation and sheathing copper wire braided total shielding J grade K grade compensation flexible cable for thermocouples |
KX-HA-FPFP | Fluorine plastic insulation and sheathing copper wire braided split screen plus total shielding J grade K grade compensation cable for thermocouples |
KX-HA-FPFRP | Compensated flexible cable for thermocouples with fluorine plastic insulation and sheathed copper wire braided split screen plus shielding J grade K grade |
KX-HA-FVP | Fluoroprene insulated polyvinyl chloride sheathed copper wire braided total shielding J grade K grade compensation cable for thermocouples |
KX-HA-FVRP | Fluoroprene insulated polyvinyl chloride sheathed copper wire braided total shielding J grade K grade compensation flexible cable for thermocouples |
KX-HA-FPVP | Fluorine plastic insulated polyvinyl chloride sheathed copper wire braided split screen plus total shielding J grade K grade compensation cable for thermocouples |
KX-HA-FPVRP | Fluorine plastic insulated polyvinyl chloride sheathed copper wire braided split screen plus total shielding J grade K grade compensation flexible cable for thermocouples |
KX-HA-FGP | Fluoroprene insulated silicone rubber sheathed copper wire braided total shielding J grade K grade compensation cable for thermocouples |
KX-HA-FGRP | Fluoroprene insulated silicone rubber sheathed copper wire braided total shielding J grade K grade compensation flexible cable for thermocouples |
KX-HA-FPGP | Fluorine plastic insulated silicone rubber sheathed copper wire braided split screen plus total shielding J grade K grade compensation cable for thermocouples |
KX-HA-FPGRP | Fluorine plastic insulated silicone rubber sheathed copper wire braided split screen plus total shielding J grade K grade compensation flexible cable for thermocouples |
Note: 1 The above basic models only list the shielding mode of copper wire or tinned wire. For other shielding types, you only need to change the shielding code, such as P2 and P3 2 Flame retardant type plus ZR before the model, armored cable type plus 22, ZR192 for imported PFA material, temperature resistance 260℃ |
4: intrinsic safety compensation cable
IA-KX-GA-FPVP | Fluorine plastic insulated polyvinyl chloride sheathed copper wire braided split screen plus total shielding J grade K grade intrinsically safe thermocouple compensation cable |
IA-KX-GA-FPVRP | Fluorine plastic insulated polyvinyl chloride sheathed copper wire braided split screen plus total shielding J grade K grade intrinsic safety type flexible cable |
IA-KX-HA-FPFP | Fluorine plastic insulation and sheathing copper wire braided split screen plus total shielding J grade K grade intrinsically safe type thermocouple compensation cable |
IA-KX-HA-FPFRP | Fluorine plastic insulated and sheathed copper wire braided split screen plus total shielding J grade K grade intrinsic safety type flexible cable |
IA-KX-HA-FPGP | Fluorine plastic insulated silicone rubber sheathed copper wire braided split screen plus total shielding J grade K grade intrinsic safety type thermocouple compensation cable |
IA-KX-HA-FPGRP | Fluorine plastic insulated silicone rubber sheathed copper wire braided split screen plus total shielding J grade K grade intrinsic safety type flexible cable |
Note: 1 The above basic models only list the shielding mode of copper wire or tinned wire. For other shielding types, you only need to change the shielding code, such as P2 and P3 2 Flame retardant type plus ZR before the model, armored cable type plus 22, ZR192 for imported PFA material, temperature resistance 260℃ |
Five: code name and meaning
Table 2
project | Code name | description |
Flame retardant property | ZR | Grade A, B, C flame retardant |
Serial code | /IA | None (intrinsic safety type) |
Insulating material | Y | polyethylene |
YJ | Crosslinked polyethylene | |
YD | Low smoke halogen-free flame retardant polyolefin | |
F | Polyperfluorinated ethylene propylene (F46) or soluble polytetrafluoroethylene (PFA) | |
Sheath material | YD | Low smoke halogen-free flame retardant polyolefin |
V | Polyvinyl chloride | |
F | Polyperfluorinated ethylene propylene (F46) or soluble polytetrafluoroethylene (PFA) | |
G | Silicone rubber | |
Shielding material | P | Copper wire braided shielding |
P2 | Copper tape wrapped shielding | |
P3 | Aluminum-plastic composite tape wrapping shield | |
Conductor structure | A | Single conductor |
B | 7 stranded conductors | |
R | Multiple stranded conductor |
Message