DisclaimerSiteMapChineseEnglish

Compensating conductor

  • 1.jpg

Type K compensating conductor

Cable use: The series products of compensation wire and cable are suitable for the temperature cont
Description

Cable use: The series products of compensation wire and cable are suitable for the temperature control system of energy, metallurgy, petroleum, chemical industry and other factories, mining enterprises and scientific research departments. It is used for the connection between the cold end and the temperature measuring instrument. Heat resistant type adopts fluorine plastic insulation and sheath with excellent heat resistance, waterproof, anticorrosion, acid and alkali resistance, chemical resistance, wear resistance, aging resistance and non-combustion properties. Two, compensation wire cable implementation standard: GB/T4989/94 equivalent IEC584.3 Three, compensation wire cable use characteristics: 1, compensation cable use characteristics

type

Bending radius

temperature

temperature

unarmoured

armored

Fixed laying

Non-fixed laying

There are "105" in the general model and "90" in the high-temperature model

Outer diameter 6 times Outer diameter 10 times outer diameter of the cable

Outer diameter of cable 12 times

≥-40℃ ≥-60℃

≥-15℃ ≥-20℃

≤70℃
≤105℃
≤90℃
≤250℃

2. Product code and meaning:

project

Code name

Code meaning

project

Code name

Code meaning

Model number

SC

With S - indexing thermocouple compensation wire

Heat resistance class

70

The operating temperature is 70℃

RC

Use R - index thermocouple compensation conductor

105

The operating temperature is 105℃

NC

Use N - index thermocouple compensation conductor

200

The operating temperature is 200℃

NX

Use N - index thermocouple compensation conductor

250

The operating temperature is 250℃

KCA
KCB

With K - mark thermocouple compensation wire

Insulating material

V

Polyvinyl chloride

KX

With K - mark thermocouple compensation wire

Y

polyethylene

EX

Use E - index thermocouple compensation conductor

B

polypropylene

JX

A J - index thermocouple compensation conductor is used

F4

Teflon

T

With T - mark thermocouple compensation wire

F46

Polyperchloroethylene propylene

Serial code

ZR

Flame-retardant cable

Sheath material

V

Polyvinyl chloride

ia

Intrinsic cable

B

Glass fibre

Usage classification

G

General use

F4

Teflon

H

Heat resistant

F46

Polyperchloroethylene propylene

Precision class

S

j-grade

Shielding material

P

Copper wire braid

P1

Tinned copper wire braid

/

Ordinary grade

P2

Copper tape is wrapped

P3

Aluminum/plastic composite film wrap

specification


2 x conductor cross-sectional area mm2

Type of conductor


Single conductor may be omitted

R

Multiple stranded conductor

armor

22

Steel tape armor

32

Fine steel wire armor

Four, compensation wire cable technical indicators:

1. Type, alloy wire material and insulation color

Compensating conductor type

With a thermocouple

Thermocouple indexing number

Compensating wire alloy wire

Insulation color

Positive order

Negative order

Positive order

Negative order

SC

Platinum-rhodium 10-platinum thermocouple

S

SPC (Copper)

SNC

red

green

RC

Rhodium 13-platinum thermocouple

R

RPC (copper)

RNC (copper-nickel)

red

green

KCA

Nichcr - nichsi thermocouple

K

KPCA (iron)

KNCA (Copper nickel)

red

blue

KCB

KPCB (copper)

KNCB (Copper nickel)

red

blue

KX

KPX (nichrome)

KNX (nickel silicon)

red

black

NC

Nickel-chromium-silicon - nickel-silicon thermocouple

N

NPC (Iron)

NNC (copper-nickel)

red

grey

NX

NPX (nichrome silicon)

NNX (nickel silicon)

red

grey

EX

Nichrome - copper-nickel thermocouple

E

EPX (NichCR)

ENX (Copper nickel)

red

brown

JX

Iron-copper-nickel thermocouple

J

JPX (iron)

JNX (Copper-nickel)

red

The purple

TX

Copper-copper-nickel thermocouple

T

TPX (Copper)

TNX (Copper nickel)

red

white

2, the use of classified layer color

Usage classification

Accuracy grade and mark

Jacket color

Ordinary grade

j-grade

Ordinary grade

j-grade

General use

G

/

S

black

grey

Heat resistant

H

/

S

black

yellow

V. Model name of compensation wire and cable:

Product model

Product name

KXVV

Polyvinyl chloride insulation and sheathing are common for compensatory conductors and cables for thermocouples with K index

KXVV22

PVC insulated and sheathed steel tape sheathed compensation cable for common grade K grade thermocouple

KXVPV

Compensation conductors and cables for PVC insulated and sheathed copper braided sub-shielding common grade K - grade thermocouples

KXVPV22

PVC insulated and sheathed copper wire braided section-shielded steel tape sheathed compensation cable for common grade K division mark thermocouple

KXVVP

Compensation cable for PVC insulated and sheathed copper wire braided total shielding common grade K index thermocouple

KXVV22P

PVC insulated and sheathed copper wire braided total screen sheathed steel tape sheathed compensation cable for common grade K grade thermocouple

KXVPVP

Compensation cables for PVC insulated and sheathed copper wire braided sub-shielding and total shielding common grade K sub-mark thermocouples

KXVPV22

Compensation cable for PVC insulated and sheathed copper wire braided separately shielded and steel tape armoured with total shielded ordinary K division number thermocouple

KXFF

Compensation conductors and cables for fluorine plastics and sheathing common grade K - part thermocouples

KXFPF

Compensation conductors and cables for fluorine plastics and sheathed copper braided sub-shielding common grade K - grade thermocouples

KXFFP

Fluorine plastics and sheathed copper wire braided total shielding ordinary grade K - index thermocouple compensation wires and cables

KXFPFP

Compensation cables for fluorine plastics and sheathed copper wire braided sub-shielding and total shielding common grade K sub-marking thermocouples

Vi. Model description of compensation conductor and cable:

classification

Code name

classification

Code name

classification

Code name

Fire resistance symbol

Non-flame retardant

omission

Serial code

X/C

sheathing

Polyvinyl chloride

V

Flame retardant

ZR

Insulating material

Fluorine plastics

F

Low smoke and low halide polyvinyl chloride

VD

Class A flame retardant

ZA

Polyvinyl chloride

V

Low smoke halogen-free polyolefin

E

Class B flame retardant

ZB

Low smoke and low halide polyvinyl chloride

VD

Fluorine plastics

F

Class C flame retardant

ZC

Low smoke halogen-free polyolefin

E

Heat resistance

70 ℃

omission

Screen material

Copper wire/tin plating

P

armor

Steel tape armor

22

105℃, 90℃

90

Copper tape/copper plastic

P2

Fine steel wire armor

32

105 ℃

105

Aluminum tape/aluminum plastic

P3/P1

Intrinsic cable

IA

205 ℃

FF

Specifications:

Cross section (mm2)

Conductor diameter (mm)

Logarithmic range

Core number range

Special restriction

0.5

1/0.80 or 7/0.30

1,2,3, ~ 24

2

When the core is less than 4 pairs do not armor

0.75

1/0.97 or 7/0.37

1.0

1/1.13 or 7/0.43

1.5

1/1.38 or 7/0.52

2.5

1/1.78 or 7/0.68

Seven, compensation wire cable delivery length:

Cables should generally be no less than 100 meters, allowing short delivery of more than 10 meters. The quantity shall not exceed 10% of the total delivery, and the measurement error shall not exceed ±5%. If there are special requirements, both parties can negotiate separately.



Message
Return To The Top