Compensating conductor

  • 1.jpg

Built-in high temperature compensation cable

First, the characteristics and uses of this high temperature compensation cable The compensation c
Description

First, the characteristics and uses of this high temperature compensation cable

The compensation cable for thermocouple of intrinsically safe explosion-proof temperature measuring system is a cable composed of multiple pairs of intrinsically safe explosion-proof temperature measuring system with compensation wires. Besides the performance of other compensation cables, it also has explosion-proof safety performance. It is suitable for the environment with explosion risk and the occasion of high explosion-proof safety performance. The cold end of the extended explosion-proof thermocouple and the explosion-proof thermometer are connected to form the intrinsically safe explosion-proof temperature measuring system.

Two, the implementation of standards

This product implements GB/4989-94 equivalent to IEC584-3 standard

Flame retardant properties in line with GB12666-5(IEC332-3) requirements

Three, the use of the high temperature compensation cable

1, the use of temperature: heat resistance grade: 180℃ ordinary grade: 70℃ and 105℃;

2. * Low ambient temperature:

Fluorine plastic insulation flame retardant PVC sheath:

Fixed laying: -40℃, non-fixed laying: -15℃;

Fluorine plastic insulation silicone rubber sheath:

Fixed laying: -60℃, non-fixed laying -20℃;

3, cable installation and laying temperature: flame retardant PVC sheath is not less than 0℃, silicone rubber sheath is not less than -25℃;

4. Allowable bending radius: copper tape shielded winding cable should not be less than 12 times of cable diameter, and other cables should not be less than 6 times of cable diameter.

Iv. Model and name of this high temperature compensation cable

Type numberName of the product
ZR-ia-KX-GSVPVPFlame retardant polyvinyl chloride insulation and sheathed precision single conductor copper wire braided split screen, total screen, K division number of thermocouples with intrinsic safety compensation cable
ZR-ia-KX-GSVPVRPFlame retardant polyvinyl chloride insulation and sheathing precision grade multi-strand conductor copper wire braided split screen, total screen, K division number of thermocouple with intrinsic safety compensation flexible cable
ZR-ia-KX-GSVPLVPLFlame retardant polyvinyl chloride insulation and sheathing precision grade single conductor aluminum-plastic composite tape wrapped split screen, total screen, K division number of thermocouple with intrinsic safety compensation cable
ZR-ia-KX-GSVPLVRPLFlame retardant polyvinyl chloride insulation and sheathing precision grade multi-strand conductor aluminum-plastic composite tape wrapped split screen, total screen, K division number of thermocouple with intrinsic safety compensation flexible cable
ZR-ia-KX-GSVP2VP2Flame retardant polyvinyl chloride insulation and sheathing precision single conductor copper plastic composite tape wrapped split screen, total screen, K division number of thermocouple with intrinsic safety compensation cable
ZR-ia-KX-GSVP2VRP2Flame retardant polyvinyl chloride insulation and sheathing precision single conductor copper plastic composite tape wrapped split screen, total screen, K division number of thermocouple with intrinsic safety compensation flexible cable
ZR-ia-KX-GSFPVPFluorine plastic insulation flame retardant polyvinyl hydrogen sheathed precision single conductor copper wire braided split screen, total screen, K division number of thermocouple with intrinsic safety compensation cable
ZR-ia-KX-GSFPVRPFluorine plastic insulation flame retardant polyvinyl hydrogen sheathed precision multi-strand conductor copper wire braided split screen, total screen, K division number of thermocouple with intrinsic safety compensation flexible cable
ZR-ia-KX-GSFPVPLVPLFluorine plastic insulation flame retardant polyvinyl hydrogen sheathed precision grade multi-strand conductor aluminum-plastic composite tape wrapped split screen, total screen,K division number thermocouple for intrinsic safety compensation cable
ZR-ia-KX-GSFPVPLVRPLFluorine plastic insulation flame retardant polyvinyl hydrogen sheathed precision grade multi-strand conductor aluminum-plastic composite tape wrapped split screen, total screen, K division number of thermocouple with intrinsic safety compensation flexible cable
ZR-ia-KX-GSFP2VP2Fluorine plastic insulation flame retardant polyvinyl chloride sheathed precision single-strand conductor aluminum-plastic composite tape wrapped split screen, total screen, K division number thermocouple for intrinsic safety compensation cable
ZR-ia-KX-GSFP2VRP2Fluorine plastic insulation flame retardant polyvinyl chloride sheathed precision single-strand conductor aluminum-plastic composite tape wrapped split screen, total screen, K division number of thermocouple with intrinsic safety compensation flexible cable
ia-KX-HSFPGPFluorine plastic insulated silicone rubber sheathed precision single conductor copper wire braided split screen, total screen, K division number of thermocouple with intrinsic safety compensation cable
ia-KX-HSFPGRPFluorine plastic insulation silicone rubber sheathing precision grade multi-strand conductor copper wire braided split screen, total screen,

Intrinsic safety compensation flexible cable for K - mark thermocouple

ia-KX-IMHSFPGPImported fluorine plastic insulation silicone rubber sheathed precision single conductor copper wire braided split screen, total screen, K division number thermocouple with intrinsic safety compensation cable
ia-KX-IMHSFPGRPImported fluorine plastic insulation silicone rubber sheathed precision single conductor copper wire braided split screen, total screen, K division number thermocouple with intrinsic safety compensation flexible cable


Message