Silicone rubber flat cable
Description
A: product features and uses
This product uses silicone rubber as insulation or sheath material. Because silicone rubber itself has the characteristics of high temperature resistance, cold resistance, softness, wear resistance and corrosion resistance, the electrical performance of the cable is stable in high temperature environment, good aging resistance and long service life. Suitable for AC 1KV and below with tensile resistance, heat resistance, anti-corrosion and other special requirements of driving, trolley, transmission machinery and electrical equipment with power transmission lines and control, lighting, communication lines, this product has been widely used in metallurgy, electric power, chemical industry, shipbuilding, port and other industries.
Flat phase shielded silicone rubber sheathed cable is suitable for inverter power supply cable.
Two: product implementation standards
Q/HHTZH007.4
Three: Use features
1. Rated AC voltage: U0/U 0.6/1KV
z.u high operating temperature: 180℃
z.u Low ambient temperature: -60℃ for fixed installation
2. The cable installation and laying temperature should not be lower than -25 ° C.
Four: basic model and name
Table 1
Model number | Product name |
YGGB | Flat flexible cable for moving with silicone rubber insulated and sheathed tinned copper wire |
YGCB-VFR | Flat flexible cable for moving with nitrile insulated silicone rubber sheathed |
YGCB-HF46R | F46 insulated silicone rubber sheathed flat flexible cable for moving |
YGCBP | Flat flexible cable for mobile use with silicone rubber insulation and sheathed tinned copper braided phase shielding |
YGCB-VFRP | Flat flexible cable for mobile use with nitrile insulated silicone rubber sheathed tinned copper braided phase shielding |
YGCB-HF46RP | F46 insulated silicone rubber sheathed tinned copper wire braided phase shielding flat flexible cable for mobile use |
Note: The copper wire in the conductor core can be tinned.
Five: code name and meaning
Table 2
Code name | Code meaning |
Y | Mobile series |
G | Silicone rubber insulation or sheath |
VF | Nitrile insulation |
B | Flat type |
P | Copper wire (tinned copper wire) shield |
F46 | Polyperfluoroethylene propylene |
Six: main technical indicators
1. Dc resistance of finished cable conductor (Class R) (conforming to GB3956) refer to Table 2 in Appendix A.
2.20 ℃ Insulation resistance shall not be less than 100ω /KM.
3. The finished cable is not broken down by AC 50HZ3.5KV/5min voltage test.