YFFB flat cable
Description
This product has the characteristics of cold resistance, soft, wear resistance, oil proof, suitable for the rated AC voltage 0.6/1KV and below with cold resistance, oil proof and other special requirements for mobile electrical connection cables, the product has been widely used in metallurgy, electric power, shipbuilding, automobile manufacturing and other industries.
Two: product implementation standard Q/HL009-2004. Flame retardant performance test GB12666-90
Three: Use features
1. Rated AC voltage: U0/U 0.6/1KV z.i High operating temperature: 105℃ z.i Low ambient temperature: -40℃ for fixed installation
2. The cable installation and laying temperature should not be lower than -25 ° C.
3. The allowable bending radius of the cable is 12 times of the outer diameter of the cable
Four: basic model and name
Table 1 Models and product names
YVFR Nitrile insulated and sheathed power flexible cable
YVFRP nitrile insulated and sheathed copper braided shielded power flexible cable
ZR-YVFR Flame retardant nitrile insulated and sheathed power flexible cable
ZR-YVFRP flame retardant nitrile insulated and sheathed copper braided shielded power flexible cable
YVFPR nitrile insulated and sheathed shielded flexible cable
YVFRP2 nitrile insulated and sheathed copper foil shielded power flexible cable
YVFRB nitrile insulated and sheathed power soft flat cable
YVFRPB nitrile insulated and sheathed copper braided shielded power soft flat cable
YVFB Nitrile insulated and sheathed mobile flat cable
YVFPB nitrile insulated and sheathed copper braided shielded mobile flat cable
YVFP2B Nitrile insulated and sheathed copper foil shielded mobile flat cable
ZR-YVFRPB flame retardant nitrile insulated and sheathed copper braided shielded mobile flat cable cable
NH-YVFR Fire-resistant butyronitrile insulated and sheathed power flexible cable
NH-YVFRP refractory nitrile insulated and sheathed copper braided shielded power flexible cable
KYVFR Nitrile insulated and sheathed control flexible cable
KYVFRP nitrile insulated and sheathed copper braided shielding control flexible cable
ZR-KYVFR Flame retardant nitrile insulated and sheathed control flexible cable
ZR-KYVFRP flame retardant nitrile insulated and sheathed copper braided shielding control flexible cable
KYVFPR nitrile insulated and sheathed shielded control flexible cable
KYVFRP2 Nitrile insulated and sheathed copper foil shielded control flexible cable
YVFP nitrile insulated and sheathed shielded power cable
KYVFP nitrile insulated and sheathed copper braided shielding control cable
ZR-KYVFP flame retardant nitrile insulated and sheathed shielded control cable
ZR-KVFP2 Flame retardant nitrile insulated and sheathed copper foil shielded control cable
YVFP2 nitrile insulated and sheathed copper foil shielded power cable
KYVFB Nitrile insulated and sheathed control flat cable
ZR-YFFB flame retardant nitrile composite insulated and sheathed moving flat flexible cable
ZR-YFFPB flame retardant nitrile composite insulated and sheathed copper wire shielded mobile flat flexible cable
YFFB nitrile complex insulation and sheathing move flat flexible cables
YFFBP nitrile complex insulation and sheathed copper wire shielding mobile flat flexible cable
YFFRB nitrile complex insulation and sheathing move flat flexible cables
YFFRBP nitrile complex insulation and sheathed copper wire shielding mobile flat flexible cable
YFF nitrile complex insulated and sheathed cable
YFFP nitrile composite insulated and sheathed copper wire shielded cable
Table 2 Code Name Meaning YVF Nitrile cable Series P copper braided shield R multi-strand stranded conductor B flat cable
Six: main technical indicators
1. Dc resistance of finished cable conductor (Class R) (conforming to GB3956) refer to Table 2 in Appendix A.
2.20 ℃ Insulation resistance shall not be less than 50MΩ/KM.
3. The finished cable is not broken down by AC 50HZ3.5KV/5min voltage test.
Message