High temperature and oil resistant special cable
Description
I. Overview:
High temperature and oil resistant special cable is suitable for metallurgy, petroleum, chemical industry and power plants and other industrial and mining enterprises, in high temperature conditions and harsh environment (such as acid, alkali, oil and water low temperature conditions) as a connection line of various electrical appliances, meters and automatic devices, for rated AC voltage 450/750 volts and below the control, monitoring and protection of the circuit packing occasions. Ii. Model and Name:
Serial number | Model number | name |
1 | KFF | Fluorine plastic insulated and sheathed control cable |
2 | KFFP | Fluorine plastic insulated and sheathed shielded control cable |
3 | KFFR | Fluoroplastic insulated and sheathed control flexible cable |
4 | KFFRP | Fluoroplastic insulated and sheathed shielded control flexible cable |
5 | KFV | Fluoroplastic insulated polyvinyl chloride sheathed control cable |
6 | KFVP | Fluoroplastic insulated polyvinyl chloride sheathed shielded control cable |
7 | KFVR | Fluoroplastic insulated polyvinyl chloride sheathed control flexible cable |
8 | KFVRP | Fluoroplastic insulated polyvinyl chloride sheathed control flexible cable |
9 | KFV22 | Fluorine plastic insulated polyvinyl chloride sheathed steel tape armoured control cable |
10 | KFVP22 | Fluoropolytic-insulated polyvinyl chloride sheathed steel tape armoured shielded control cable |
11 | KFVR22 | Fluorine plastic insulated PVC sheathed steel tape armoured control flexible cable |
12 | KFVRP22 | Fluoropolytic-insulated polyvinyl chloride sheathed steel tape armoured shielded control flexible cable |
13 | KFFV22 | Fluorine plastic insulated and inner sheathed polyvinyl chloride outer sheathed steel tape armoured control cable |
14 | KFFRV22 | Fluorine plastic insulated and inner sheathed polyvinyl chloride outer sheathed steel tape armoured control flexible cable |
1, rated voltage: AC Uo/U; 2. Working temperature: No. 1 ~ 4-60 ~ +200℃ No. 5 ~ 14-15 ~ +105℃ 3, insulation resistance (20℃) not less than 50MΩ·km 4, conductor core DC resistance (20℃) in accordance with GB3956-97 regulations 5, unarmored cable allowed bending radius is not less than 6 times of the cable diameter, The bending radius of armored cable is not less than 12 times the outer diameter of the cable. 6, low installation and laying temperature: serial number 1 ~ 4-45 ℃ Serial number 5 ~ 14 0℃
Serial number | Nominal section | Conductor core specification | Conductor core specification | Number of cable cores | ||
Serial number One, two, five, six, nine, ten, thirteen | Serial number 3,4,7,8,11,12,14 | Serial number 1 ~ 4 | Serial number 5 ~ 8 | Serial number 9 ~ 14 | ||
1 2 3 4 5 | 0.2 0.5 0.75 1.0 1.5 2.5 | 1/0.52 1/0.80 1/1.0 1/1.13 1/1.38 1/1.76 | 7/0.20 16/0.20 19/0.23 24/0.20 19/0.26 32/0.20 19/0.32 30/0.25 49/0.26 | 2 ~ 44 2 ~ 30 2 ~ 19 2 ~ 16 2 ~ 14 2 ~ 8 | 2 ~ 61 | 7 ~ 37 7 ~ 37 7 ~ 37 4 ~ 37 |