Low smoke halogen free cable
Description
1. Features and Uses: low-smoke halogen-free cable products are suitable for subway, high-rise buildings, shopping malls, theaters, power stations, chemical factories, city squares and other public utilities with rated AC voltage of 450/750V and below where the flame-retardant characteristics of cables are highly required. The characteristics of halogen free and low smoke, low halogen and low smoke, when the fire occurs, the spread speed is slow, the smoke concentration is low, the visibility is high, the release of harmful gas is small, easy to evacuate personnel. The corrosion of combustion gas is small, but also to avoid damage to instruments and equipment, low halogen, halogen free characteristics, so that the cable material in aging resistance and UV resistance and other radiation performance is greatly extended, thus extending the use of cable. Two, product implementation standard: GB9330-88Q/WTL11-2003 Three, use characteristics: 1. Cable rated voltage UO/U:450/750V, AC polyolefin UO/U is 0.6/1KV 2. Long-term working temperature of cable :-20℃-90℃, -40℃-105℃ 3. Bending radius: not less than 6 times of the outer diameter of unarmored cables, and not less than 12 times of the outer diameter of cables with armored or copper tape shielding structure. Four, the main indicators: 1. The cable should withstand the power frequency voltage test at the ambient temperature of 3kV, 5min no breakdown 2. The transmittance of the cable should comply with the following table
Cable outer diameter D(mm) | Transmittance (%)≥ | Cable outer diameter D(mm) | Transmittance (%)≥ |
D > 40 | 70 | 5 < D≤10 | 50 |
10 < D≤40 | 60 | D 5 or more | 40 |
3. Cable non-delay flammability (flame retardant characteristics): should pass GB12666.5-90 class B bunch-burning test. Single wire and cable vertical combustion test should pass GB12666.2-90 4. 5. The PH value and conductivity of the combustion gas are 754-2 pH ≥4.3 conductivity ≤10μS/mm. V. Basic Model and Name:
Model number | name |
DLD-KVV | Copper core low smoke low halide polyvinyl chloride insulated and sheathed control cable |
DLD-KVVP | Copper core low smoke low halide polyvinyl chloride insulated and sheathed copper mesh braided shielding control cable |
DLD-KVV22 | Copper core low smoke low halide polyvinyl chloride insulated and sheathed steel tape armoured control cable |
WLD-KJEG | Copper core halogen-free low smoke cross-linked polyolefin insulated thermosetting sheathed control cable |
WLD-KJEGP | Copper core halogen-free low smoke crosslinked polyolefin insulated thermosetting sheathed copper screen control cable |
WLD-KJEGP2-22 | Copper core halogen-free low smoke crosslinked polyolefin insulated thermosetting sheathed copper tape screen steel tape armoured control cable |
WLD-KJES | Copper core halogen-free low smoke crosslinked polyolefin insulated thermoplastic sheathed control cable |
WLD-KJESP | Copper core halogen-free low smoke crosslinked polyolefin insulated thermoplastic sheathed copper screen control cable |
WLD-KJES22 | Copper core halogen-free low smoke crosslinked polyolefin insulated thermoplastic sheathed steel tape armoured control cable |
DLD-KSF | Copper core low smoke low halogen thermoplastic insulated nitrile thermoplastic body sheathed control cable |
DLD-KSFP | Copper core low smoke low halogen thermoplastic insulation nitrile thermoplastic body sheathed copper screen control cable |
DLD-KSFP2-22 | Copper core low smoke low halogen thermoplastic insulated nitrile thermoplastic body sheathed copper tape shield steel tape armoured control cable |
Vi. Model Description Code, Name and Meaning:
project | Code name | meaning |
Serial code | DLD WLD K | Low smoke and low halogen Low smoke and no halogen Control cable |
Insulating material | V J E F | Polyvinyl chloride crosslinking polyolefin Nitrile thermoplasticizer |
Sheath material | V G S | Polyvinyl chloride Thermosetting sheath Thermoplastic sheath |
Shielding material | P P2 | Copper mesh or tinned copper mesh Copper/plastic composite tape |
Armored material | 22 32 | Steel strip Fine wire |
Type of conductor | A B R | d.u conductor 7 stranded conductors Multiple stranded conductor |
Vii. Scope of Production:
Cross section mm2 | 0.5 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 |
Number of cores | 2-81. | 2-81. | 2-81. | 2-50 | 2-37 | 2-20 | 2-19 | 2-14 | 2-10 |
Note: Other cables of the same size and material can be produced according to customer's requirements.
Message